MultiSafe TT 3
MultiSafe TT 3 bei der Spannungsprüfung für Schienenverkehr

Telescope voltage tester TT 3

up to 3000 V AC and DC

3 kV AC / 3 kV DCTelescope up to 10 m

The MultiSafe TT 3 is a telescopic voltage tester for fast voltage testing on overhead railway lines and outdoor switchgear. Its quick and easy-to-use telescope system makes work easier and saves time.

Fully automatic measuring sequences and only one button eliminate operating errors. Its integrated self-test enables the quick functional testing of the device on site without further aids. With different sizes and ground connections, we offer the ideal test device for every application.

Its 360° visual display system, complemented by LCD display and audible warning, guarantee good perception in all environments.The sealed protective resistors reduce the high voltage to a harmless level. We guarantee the highest safety through surge voltage tests > 100 kV and the unique TST saftey module with continuous redundant monitoring.

Tietzsch Animation für MultiSafe TT 3
Product video telescopic voltage testers TT
  • nominal voltage range:
    50 – 3 000 V AC / 50 – 3 000 V DC
  • display range:
    40 – 3 000 V AC / 40 – 3 000 V DC
  • integrated self-test
  • response voltage Ut 400 V (red / green change)
  • 1,8 m spiral cable with 6 kV isolation
    with universal clamp for fixed ball points and earthing bar
  • test height variable up to approx. 10 m,
    transport length approx. 2,20 m, 6−part
  • due to its heavy weight, size XL is only recommended for operations above 8 m!
  • nominal voltage range:
    50 – 3 000 V AC / 50 – 3 000 V DC
  • display range:
    40 – 3 000 V AC / 40 – 3 000 V DC
  • integrated self-test
  • response voltage Ut 400 V (red / green change)
  • 1,8 m spiral cable with 6 kV isolation
    with rail foot clamp for rail
  • test height variable up to approx. 10 m,
    transport length approx. 2,20 m, 6−part
  • due to its high weight, the XL size is only recommended for use over 8 m!
  • nominal voltage range:
    50 – 3 000 V AC / 50 – 3 000 V DC
  • display range:
    40 – 3 000 V AC / 40 – 3 000 V DC
  • integrated self-test
  • response voltage Ut 400 V (red / green change)
  • 1,8 m spiral cable with 6 kV isolation
    with contact magnet for rail
  • test height variable up to approx. 10 m,
    transport length approx. 2,20 m, 6−part
  • due to its high weight, the XL size is only recommended for use over 8 m!
  • nominal voltage range:
    50 – 3 000 V AC / 50 – 3 000 V DC
  • display range:
    40 – 3 000 V AC / 40 – 3 000 V DC
  • integrated self-test
  • response voltage Ut 400 V (red / green change)
  • 1,8 m spiral cable with 6 kV Isolierung
    with universal clamp for fixed ball points and earthing bar
  • test height variable up to approx. 8,2 m,
    transport length approx. 1,71 m, 6−part
  • nominal voltage range:
    50 – 3 000 V AC / 50 – 3 000 V DC
  • display range:
    40 – 3 000 V AC / 40 – 3 000 V DC
  • integrated self-test
  • response voltage Ut 400 V (red / green change)
  • 1,8 m spiral cable with 6 kV isolation
    with rail foot clamp for rail
  • test height variable up to approx. 8,2 m,
    transport length approx. 1,71 m, 6−part
  • nominal voltage range:
    50 – 3 000 V AC / 50 – 3 000 V DC
  • display range:
    40 – 3 000 V AC / 40 – 3 000 V DC
  • integrated self-test
  • response voltage Ut 400 V (red / green change)
  • 1,8 m spiral cable with 6 kV isolation
    with contact magnet for rail
  • test height variable up to approx. 8,2 m,
    transport length approx. 1,71 m, 6−part
  • nominal voltage range:
    50 – 3 000 V AC / 50 – 3 000 V DC
  • display range:
    40 – 3 000 V AC / 40 – 3 000 V DC
  • integrated self-test
  • response voltage Ut 400 V (red / green change)
  • 1,8 m spiral cable with 6 kV isolation
    with universal clamp for fixed ball points and earthing bar
  • test height variable up to approx. 6,2 m,
    transport length approx. 1,71 m, 4−part
  • nominal voltage range:
    50 – 3 000 V AC / 50 – 3 000 V DC
  • display range:
    40 – 3 000 V AC / 40 – 3 000 V DC
  • integrated self-test
  • response voltage Ut 400 V (red / green change)
  • 1,8 m spiral cable with 6 kV isolation
    with rail foot clamp for rail
  • test height variable up to approx. 6,2 m,
    transport length approx. 1,71 m, 4−part
  • nominal voltage range:
    50 – 3 000 V AC / 50 – 3 000 V DC
  • display range:
    40 – 3 000 V AC / 40 – 3 000 V DC
  • integrated self-test
  • response voltage Ut 400 V (red / green change)
  • 1,8 m spiral cable with 6 kV isolation
    with contact magnet for rail
  • test height variable up to approx. 6,2 m,
    transport length approx. 1,71 m, 4−part
  • nominal voltage range:
    50 – 3 000 V AC / 50 – 3 000 V DC
  • display range:
    40 – 3 000 V AC / 40 – 3 000 V DC
  • integrated self-test
  • response voltage Ut 400 V (red / green change)
  • 1,8 m spiral cable with 6 kV isolation
    with universal clamp for fixed ball points and earthing bar
  • test height variable up to approx. 6,2 m,
    transport length approx. 1,41 m, 6−part
  • nominal voltage range:
    50 – 3 000 V AC / 50 – 3 000 V DC
  • display range:
    40 – 3 000 V AC / 40 – 3 000 V DC
  • integrated self-test
  • response voltage Ut 400 V (red / green change)
  • 1,8 m spiral cable with 6 kV Isolierung
    with rail foot clamp for rail
  • test height variable up to approx. 6,2 m,
    transport length approx. 1,41 m, 6−part
  • nominal voltage range:
    50 – 3 000 V AC / 50 – 3 000 V DC
  • display range:
    40 – 3 000 V AC / 40 – 3 000 V DC
  • integrated self-test
  • response voltage Ut 400 V (red / green change)
  • 1,8 m spiral cable with 6 kV isolation
    with contact magnet for rail
  • test height variable up to approx. 6,2 m,
    transport length approx. 1,41 m, 6−part
MultiSafe TT 3

1.220,001.905,00

Excl. VAT (in the EU), plus shipping costs

Delivery time: max. 10 weeks (exact delivery date with OC)

Voltage tester:
  • precise display of the voltage 50 V – 3 000 V AC / DC
  • response voltage U400 V (other response voltages from 50 V on request)
  • large two-color illuminated display (red / green), for a clear warning of dangerous voltages
  • clear LED indicator for dangerous voltage
  • 360° illuminated band lights up (red / green) in all directions
  • acoustic warning of dangerous voltage
Safety:
  • integrated self-test for quick checking of the protective resistors, connecting cable, display and electronics
  • surge voltage strength >100 kV
  • highest degree of safety provided by molded protective resistors
Further functions:
  • telescope system for easy and quick testing
  • variable test height up to approx. 10 meters
  • for indoor and outdoor use
  • various test electrodes for testing contact wires, overhead lines and busbars
  • easy operation with just one button
  • robust housing
  • IP 65 – waterproof
Tech. data TT 3 (3 kV)
TT 3MTT 3STT 3LTT 3XL
Nominal voltage50 - 3 000 V AC
50 - 3 000 V DC
Display range50 - 3 000 V AC
50 - 3 000 V DC
Frequency rangeDC / 15 - 500 Hz
Test height approx. up to6,2 m8,2 m10 m
Transport length1,65 m1,35 m1,65 m2,14 m
Telescopic system4 part6 part
Frequency indicationyes
Voltage test against ground potentialyes
Voltage test phase to phase / +pole to -poleno
Indicator groupI (optical)
and
III (acustic)
LED indicator red / greenyes
Two-color LCD displayyes
Integrated self-testyes
Power supply6 x 1,5 V AA
Surge voltage strength100 kV
For indoor applicationsyes
For outdoor applicationsyes
For use in moist environments (rain)yes
Degree of protectionIP 65
Fixed connection to ground potentialmagnet or railfoot-clamp or universal-clamp
Ground connection line1,8 m - spiralcable
6 kV isolated
Interchangeable electrode shapeyes
Art.-no.89381-MA (with magnet)
89381-SK (with railfoot-clamp)
89381-UK (with universal-clamp)
89380-MA (with magnet)
89380-SK (with railfoot-clamp)
89380-UK (with universal-clamp)
89382-MA (with magnet)
89382-SK (with railfoot-clamp)
89382-UK (with universal-clamp)
89383-MA (with magnet)
89383-SK (with railfoot-clamp)
89383-UK (with universal-clamp)
Product dimensions and weight1650 x 120 x 110 mm

3,5 kg with magnet
3,8 kg with railfoot-clamp
4,3 kg with universal-clamp
1350 x 120 x 110 mm

4,1 kg with magnet
4,4 kg with railfoot-clamp
4,9 kg with universal-clamp
1650 x 120 x 110 mm

4,5 kg with magnet
4,8 kg with railfoot-clamp
5,3 kg with universal-clamp
2140 x 120 x 110 mm

5,5 kg with magnet
5,8 kg with railfoot-clamp
6,3 kg with universal-clamp
Product packaged dimensions and weight1710 x 200 x 190 mm

5,5 kg with magnet
5,8 kg with railfoot-clamp
6,3 kg with universal-clamp
1410 x 200 x 190 mm

6,1 kg with magnet
6,4 kg with railfoot-clamp
6,9 kg with universal-clamp
1710 x 200 x 190 mm

6,5 kg with magnet
6,8 kg with railfoot-clamp
7,3 kg with universal-clamp
2200 x 200 x 190 mm

7,5 kg with magnet
7,8 kg with railfoot-clamp
8,3 kg with universal-clamp